control_surface_troubleshooting [2011/06/21 12:30]
orange_hand
control_surface_troubleshooting [2011/06/22 09:42]
orange_hand Various corrections
Line 22: Line 22:
 The first step to do a successful trouble shooting is to understand the design of the CS PCB. Attached you will find an overview of the usage of the connection pads between the CS and the Base PCB: The first step to do a successful trouble shooting is to understand the design of the CS PCB. Attached you will find an overview of the usage of the connection pads between the CS and the Base PCB:
  
-{{:20110621_cs_and_base_pcb_connector_overview.jpg|}}+{{:wiki:​20110622_mb6582_v2_cs_connector_overview.jpg|}}
  
 Please note that the all switches and all LED’s are sharing the same GND pad JD8 ! This is important to understand because if you have shorts between JD8 rails you will find that a series of switches or LED’s are not working appropriately. In this case the MB6582 firmware will not be able to distinguish between switches connected to the faulty rails. Also all the LED’s connected to the faulty rails will light up together. ​ Please note that the all switches and all LED’s are sharing the same GND pad JD8 ! This is important to understand because if you have shorts between JD8 rails you will find that a series of switches or LED’s are not working appropriately. In this case the MB6582 firmware will not be able to distinguish between switches connected to the faulty rails. Also all the LED’s connected to the faulty rails will light up together. ​
Line 39: Line 39:
 **LED Assignment Matrix** **LED Assignment Matrix**
  
-{{:20110621_cs_pcb_led_assignment_matrix.jpg|}}+{{:wiki:​20110622_mb6582_v2_cs_led_assignment_matrix.jpg|}}
  
 **Switch Assignment Matrix** **Switch Assignment Matrix**
  
-{{:20110621_cs_pcb_switch_assignment_matrix.jpg|}}+{{:wiki:​20110622_mb6582_v2_cs_switch_assignment_matrix.jpg|}}
  
 **Encoder Assignment Matrix** **Encoder Assignment Matrix**
  
-{{:20110621_cs_pcb_encoder_assignment_matrix.jpg|}}+{{:wiki:​20110622_mb6582_v2_cs_encoder_assignment_matrix.jpg|}}
  
 Check the function of each component on the CS PCB: Check the function of each component on the CS PCB:
- 
  
   - LED Matrix –> Use the cable described in point a) above to check the wiring from the connection points. You need to connect the GND wire to one connection point on the JD8 pad and the +5V wire to one connection point on the JD6 pad. Please use the LED Assignment Matrix shown below. You need to check all 64 combinations to make sure that the complete matrix LED’s are working appropriately. During this test only single LED’s should light up. If more than one LED’s lights up then you have got a short on the PCB.   - LED Matrix –> Use the cable described in point a) above to check the wiring from the connection points. You need to connect the GND wire to one connection point on the JD8 pad and the +5V wire to one connection point on the JD6 pad. Please use the LED Assignment Matrix shown below. You need to check all 64 combinations to make sure that the complete matrix LED’s are working appropriately. During this test only single LED’s should light up. If more than one LED’s lights up then you have got a short on the PCB.
Line 59: Line 58:
 If you haven’t found any faults so far you can start testing your CS while connected to the Base PCB. Please use the following verification sheet to test the function of each component of the control surface: If you haven’t found any faults so far you can start testing your CS while connected to the Base PCB. Please use the following verification sheet to test the function of each component of the control surface:
  
-{{:20110621_cs_pcb_validation_sheet.jpg|}}+{{:wiki:​20110622_mb6582_v2_cs_validation_sheet.jpg|}}
  
 You should walk through all components ! Please document your test results on the validation sheet in order to support the later troubleshooting in the forum. You should walk through all components ! Please document your test results on the validation sheet in order to support the later troubleshooting in the forum.
  
control_surface_troubleshooting.txt · Last modified: 2012/04/25 18:08 by orange_hand